Basic Info.
Type
Twin-Screw Compressor
Transport Package
Wooden Case
Specification
Acutal Size
Product Description
150A/W-750W Screw Compressor
Provide you with energy saving
Excellent compressorExcellent energy efficiency Stable performance |
High quality core components Screw host is just like the heart of screw compressor. Its performance directly affects the energy efficiency and service life of the whole machine. It adopts Atlas Copco host. SAP line saves more than 5% energy than similar products in the market. High machining accuracy, small vibration and low noise of the host. SK-F heavy-duty bearing and high stiffness rotor ensure long-life and reliable operation. |
Electrical system Standardized design, safe and reliable. Professional wiring interface, reasonable, concise and clear wiring, which is conducive to maintenance. Schneide-r and Siemens' high configuration series components ensure long-term safe use. |
Oil cooled integrated permanent magnet motor (opm+) IE4 ultra efficient oil cooled permanent magnet motor has a wide range of speed regulation, and can achieve an efficiency of more than 90% even at low speed No need for cooling fan, quieter Die cast integrated shell, effectively reducing motor vibration |
Vacuum intake valve The pressure loss is extremely low, which is more energy-saving. There are few moving parts, no "spring", "servo cylinder" and other vulnerable parts, and the service life is increased by ten times. Maintenance free. |
Air cooled permanent magnet motor (pm+ model) IE4 is super efficient and more energy-saving SK-F Bearing ensures that the motor has an ultra long service life of IP54 protection grade, and can operate without worry under harsh working conditions |
Efficient and powerful cooling design Separation design of fan and cooler: effectively prevent the leakage of cooler, and make the cleaning and maintenance of cooler more convenient. Super large oil cooler design: even in the environment of high temperature and dust, the lubricating oil temperature can be kept in the normal range to ensure the safety of the compressor in summer. |
Frequency conversion type Energy saving control |
The variable frequency air compressor can track the change of air demand and automatically adjust the motor speed, with an average energy saving of 30% or more.
Ordinary air compressors deal with the fluctuation of air demand by setting a wide pressure. They load when the air load is high and unload when the load is low, so the pressure of the system is high and the energy consumption is high; Due to the fluctuation of air demand, the compressor is unloaded for a long time, resulting in a waste of energy.
The working pressure set by the variable frequency air compressor is the pressure required by the customer. The pressure of the whole system is low. Because it can be adjusted with variable speed, it can meet the needs of customers at low load, and there is almost no unloading, so there is no unnecessary energy consumption.
150A/W-750W Model
Model | Exhaust pressure | Flow | Power | Overall dimension | Weight (air / water cooled) kg | Outlet size | Water inlet and outlet |
bar | m3/min | kW | LxWxH mm |
150A/W | 7.5 | 21.2 | 110 | 2260x1230x1600 Air cooling 2366x1200x1600 Water cooling | 1870/2400 | G 2" Air cooling DN65 Water cooling | G1 1/4" |
8.5 | 20 |
10.5 | 17.1 |
13 | 14.3 |
175A/W | 7.5 | 25 | 132 | 2260x1230x1600 Air cooling 2366x1200x1600 Water cooling | 1920/2550 | G 2" Air cooling DN65 Water cooling | G1 1/4" |
8.5 | 24.3 |
10.5 | 21 |
13 | 17 |
200A/W | 7.5 | 30.5 | 160 | 2880x1754x1930 | 2970/2870 | DN80 | G1 1/4" |
8.5 | 29.2 |
10.5 | 26.9 |
13 | 22.5 |
250A/W | 7.5 | 32.9 | 180 | 2880x1754x1930 | 3150/3050 | DN80 | G1 1/4" |
8.5 | 31.2 |
10.5 | 29.1 |
13 | 25.5 |
275A/W | 7.5 | 36.8 | 200 | 3502x1754x1983 Air cooling 2902x1754x1980 Water cooling 3602x2104x2023(6kV 10kV) | 3450/3240(380V) 4270/4040(6kV) 4770/4560(10kV) | DN100 | G2" |
8.5 | 34.4 |
10.5 | 31.3 |
13 | 28.7 |
350A/W | 7.5 | 45.8 | 250 | 3502x1754x1983 Air cooling 2902x1754x1980 Water cooling 3602x2104x2023(6kV 10kV) | 3620/3410(380V) 4500/4290(6kV) 4950/4740(10kV) | DN100 | G2" |
8.5 | 43.3 |
10.5 | 39 |
13 | 35.5 |
375A/W | 7.5 | 52.4 | 280 | 4800x2150x2250 Air cooling 3600x2150x2250 Water cooling | 5925/5490(380V) 6065/5630(6kV) 6565/6130(10kV) | DN125 | G2" |
8.5 | 50 |
10.5 | 43.7 |
13 | 39 |
425A/W | 7.5 | 55 | 315 | 5100x2150x2250 Air cooling 3600x2150x2250 380V Water cooling | 6350/5730(380V) 6410(6kV) Air cooling 7520(10kV) Aircooling | DN125 | G2" |
8.5 | 54.8 |
10.5 | 50.7 |
13 | 41.4 |
425W 6kV/10kV | 7.5 | 62.5 | 315 | 3465x1854x2100 | 4895(6kV) 4995(10kV) | DN125 | G2" |
8.5 | 60 |
10.5 | 55 |
475A/W | 7.5 | 63.5 | 355 | 5100x2150x2250 Air cooling 3600x2150x2250 380V water cooling | 6380/5760(380V) 6800(6kV) Air cooling 7520(10kV) Air cooling | DN125 | G2" |
8.5 | 63.3 |
10.5 | 56.1 |
13 | 46.2 |
475W 6kV/10kV | 7.5 | 68 | 355 | 3465x1854x2100 | 5045(6kV) 5195(10kV) | DN125 | G2" |
8.5 | 65.5 |
10.5 | 60 |
530W | 8 | 69.8 | 400 | 4535x2140x2300 | 9060(6kV) 9890(10kV) | DN150 | G2" |
10 | 60 |
13 | 49.5 |
600W | 8 | 78 | 450 | 4535x2140x2300 | 9125(6kV) 9945(10kV) | DN150 | G2" |
10 | 67.9 |
13 | 56.6 |
670W | 8 | 85.8 | 500 | 4535x2140x2300 | 10050(6kV) 10190(10kV) | DN150 | G2" |
10 | 75.4 |
13 | 63.4 |
750W | 8 | 96.5 | 560 | 4535x2140x2300 | 10100(6kV) 10330(10kV) | DN150 | G2" |
|
Note:
1.A-air cooling, W-water cooling
2.the flow is measured at the following working pressure:
-7.5bar models at 7bar
-8.5bar models at 8bar
-10.5Bar models at 10bar
-13bar models at 12.5bar
Frequency conversion series 150-350A/W OPM+/PM+ 150-350A/W OPM+/PM+Model | Exhaust pressure bar | Flow | Power | Overall dimension | Weight (air / water cooled) kg | Outlet size | Water inlet and outlet |
Min | Max | m3/min | kW | LxWxH mm |
150A/W OPM+ | 6 | 13 | 4.1-20.3 | 110 | 2454x1200x1600 Air cooling 2556x1200x1600 Water cooling | 1420/1460 | G2" Air cooling DN65 Water cooling | G1 1/4" |
|
175A/W OPM+ | 6 | 13 | 4.6-24.1 | 132 | 2454x1200x1600 Air cooling 2556x1200x1600 Water cooling | 1530/1540 | G2" Air cooling DN65 Water cooling | G1 1/4" |
|
200A/W PM+ | 6 | 10.5 | 7.3-30.1 | 160 | 2880x1754x1930 | 2890/2790 | DN80 | G1 1/4" |
|
250A/W PM+ | 6 | 10.5 | 8.0-32.7 | 180 | 2880x1754x1930 | 2960/2860 | DN80 | G1 1/4" |
|
275A/W PM+ | 6 | 10.5 | 8.4-35.8 | 200 | 3602x2104x2023 | 4110/3900 | DN100 | G2" |
|
350A/W PM+ | 6 | 10.5 | 11.0-42.6 | 250 | 3602x2104x2023 | 4280/4070 | DN100 | G2" |
|
Note:
1. A-air cooled, W-water-cooled, OPM+- oil cooled permanent magnet variable frequency motor, PM+- air cooled permanent magnet variable frequency motor;
2. The inlet temperature of cooling water should be less than 35 ºC, and the water pressure should be 0.2bar-0.6bar. At the lowest water volume, the inlet and outlet water temperature difference is 24 ºC; At the maximum water volume, the water temperature difference between inlet and outlet is 8 ºC, and the water volume should be determined according to the water quality;
3. BLT 200-350a/w pm+ can be customized to 13bar model without standard.
4. The maximum flow is measured at 7bar working pressure
Firstly we take full responsibility for what we have sold. It will our solution for any problem through ourselves or partners.
Secondly It is difficult for a user to select a qualified and reliable supplier among numerous suppliers. It is quite terrible for user to choose a poor manufacturer to work with!
YOUCHI is a specialist in gas equipment area as agents of reliable manufacturers. The bridge jobs of better communications and coordinations between manufacturers and customers are always done by us.
Thirdly generally we have fine agency prices, and provide better services attaching more importance to customers before and after sales process.
Integrity, seriousness, responsibility are our core values. We treat each business seriously and provide full services all along. What are the maintenance cost of each gas machine?
Different types have different components and maintenance cost. For the same type different sizes and performances are also different.
Take PSA oxygen generators for example, the maintenance parts mainly include air compressors, filters, and oxygen compressors if any.
What happens if maintenance is not done well?
Firstly if overly water, oil vapor, dust enter some parts absorbent like molecular sieve, these parts shall have to replaced completely. Subsequently this will affect performances of machines.
So regular maintenance is an important work to do, like replacing filter elements every 2,000 -4,000 hours.
Which method and type are the most economical?
It depends on how much gas required and its quality requirements. Different types have their advantages.
What are the utility requirements for a system?
Generally electricity power is required by each system, and some requires cooling water also. The power consumption varies from small to big sizes. For unit power consumption, normally the bigger size the less unit power consumption.
What output pressure can gas plant produce?
Different type has different normal pressures from 0.5 to 20bar. With compressor added any desired pressures are available.
For example PSA nitrogen generator gets 1-8bar, or 150bar with added nitrogen compressor.
What purity oxygen & nitrogen plant can achieve?
O2 range: 90%-99.9%.
N2 range: 95%-99.9999%
Can flow and purity be changed?
Yes available. By touching screen all parameters are regulated.
Is it dangerous for filling high pressure oxygen bottles?
Following the manual and notice to do operation is safe. Very rare there are blast for filling cylinders, unless wrong operations or poor quality of high pressure parts.
Can our local manufacture standards be followed?
Generally available. We can design and manufacture as per your country's law or regulation, like US standards ASME, CE standards PED etc.
Can the system be monitored and controlled by PC and mobile phone ?
Yes available. Complete monitoring of working parameters like flow, purity and alarms/reminders are within our capability. We have cloud monitoring to utilize cloud technology for the system.
Are onsite services available ?
Yes it is. Engineers can be sent to customers site for installation, startup, commissioning, training. Service charge USD150/day excluding travel cost.
How long to finish installation ?
Different types have different time. PSA unit takes normally 3-7 days to finish installation, startup, commissioning, training.
Cryogenic unit takes longer time, generally a month.
It also has to do with site preparation conditions and workers proficiency.
What is your payment term accepted?
20-30% down payment, balance done before or after shipment or by irrevocable L/C.
Address:
Room 1324, Xinxing International Building, No. 1288 Sanba Road, Etdz of Dezhou City, Shandong Province China
Business Type:
Manufacturer/Factory
Business Range:
Health & Medicine, Industrial Equipment & Components, Manufacturing & Processing Machinery
Management System Certification:
ISO 9001, ISO 14001, OHSAS/ OHSMS 18001, ISO 13485
Company Introduction:
YOUCHI GAS is focused on gas equipment. Firstly it is a professional supplier of gas making equipment with reliable sources, by proposing solutions to customers. Each customer′s real inquiry is taken seriously with reply and answers.
YOUCHI is mainly involved in machines of N2, O2, H2 and medical gas equipment & Ancillary devices.
Secondly YOUCHI is involved in engineering work together with its partners. These engineering include a complete process of design, development, manufacturing, assemble, installation, startup, commissioning, construction.
Meanwhile it is an integrator for some projects that require many related and auxiliary facilities. For some projects the integration is necessary to gather complete parts to make a system.
Why choose us?
Firstly we take full responsibility for what we have sold. It will our solution for any problem through ourselves or partners.
Secondly It is difficult for a user to select a qualified and reliable supplier among numerous suppliers. It is quite terrible for user to choose a poor manufacturer to work with!
YOUCHI is a specialist in gas equipment area as agents of reliable manufacturers. The bridge jobs of better communications and coordinations between manufacturers and customers are always done by us.
Thirdly generally we have fine agency prices, and provide better services attaching more importance to customers before and after sales process.
Integrity, seriousness, responsibility are our core values. We treat each business seriously and provide full services all along.